Medovia Medical Medovia Medical

ICU Hospital Therapy Ventilator (CWH-3010)

Customization: Available
Type: Ventilator
Used for: Adult, Child, Infant

Product Description

📋 Basic Information
Model NO.
CWH-3010
Screen Size
12.1 '' TFT Screen
Certification
CE, ISO13485
Kind
Medical Equipment
Group
Adult and Children
Transport Package
Standard Export Packing
Origin
China
HS Code
90192000
Capacity
5000PCS/Year
💊 Product Description
ICU Ventilator (CWH-3010)
  • Applied for adult and child
  • High-intelligent control system
  • TFT display for ventilation parameters
  • Humidifier with temperature adjustment
  • Flow (optional) and pressure trigger
  • Air compressor (optional)
Main Specifications
ModelCWH-3010
Applied forAdult and child
Control SystemHigh-intelligent control system
DisplayTFT display for ventilation parameters
AdjustmentHumidifier with temperature adjustment
Power220V AC ± 10%, 50 to 60Hz ± 2%, built-in battery for backup
Gas SourceO², Air
Ventilation ModeIPPV, SIMV, SIGH, SPONT, CPAP, PEEP, S, T, S/T and manual (optional: Bi-level)
MonitoringTidal volume, minute volume, frequency, inhaling time, airway pressure, PEEP and O² Concentration
WaveformPressure-time (optional: Flowtime, pressure-volume loop)
AlarmsNo tidal volume, minute volume too high/low, airway pressure too high/low, O² Concentration too high/low, O² or air failure, AC power failure, backup battery low
📷 Product Gallery
❓ Frequently Asked Questions
Q1: Which patient groups can use the CWH-3010 ventilator?
The CWH-3010 is designed for versatile clinical use, suitable for both adult and pediatric patients.
Q2: What ventilation modes are supported by this model?
It supports multiple modes including IPPV, SIMV, SIGH, SPONT, CPAP, PEEP, S, T, S/T, and manual operation. Bi-level mode is also available as an option.
Q3: Does the device have a backup power supply?
Yes, the CWH-3010 includes a built-in battery for backup to ensure continuous operation during AC power failures.
Q4: What parameters can be monitored on the display?
The 12.1'' TFT screen allows monitoring of tidal volume, minute volume, frequency, inhaling time, airway pressure, PEEP, and O² concentration.
Q5: What safety alarms are integrated into the system?
The system includes alarms for tidal volume issues, high/low minute volume, airway pressure fluctuations, O² concentration limits, gas source failure, and low battery.
Q6: Is an air compressor required for operation?
The device uses O² and air as gas sources. An external air compressor is available as an optional addition depending on your facility's requirements.